iluxusdesign Mix Switching Actuator meets all automation requirements in a smart building in order to meet greater comfort, security and efficiency in living spaces, residences and commercial applications. Mix Actuator used in lighting, blinds shutter, air conditioning, etc. It is a versatile device that allows a variety of configurations. It is available in two models with 12 digital potential-free contact inputs, 12 output (LXA-112-16A) and 20 output (LXA-120-16A) switching. Each channel can support a load up to 16A C characteristic and AC 230V. AC and DC shutter blind motors can be controlled and emergency scenarios can be defined. It provides solutions to different demands in projects with its scenario, logic and data converter functions.
Outputs can be controlled manually thanks to the LCD screen and buttons on the device. Contact input and output status can be monitored instantly. Mix Switching Actuators are powered by the KNX BUS and can be programmed via ETS software.
Press ‘OK’ button on the main menu. Go “PROGRAM MODE” menu with right button. Select the “PROGRAM MODE” with the “OK” button. If it is “Idle”, press “OK” to pass the programming mode. Automatically quit after programming or 120 seconds.
Press “OK” button on the main menu. Select the “OUTPUT MENU” with “OK” button. Set cursor position with right and left buttons to select the related “OUTPUT”. Press “OK” button to change the state of the related channel.
Press “OK” button on the main menu. Then the right button to go to “INPUT MENU”. With pressing “OK”, enter into “INPUT MENU”. Input channel is closed the state of input will be shown as ‘1’, otherwise 0.
To return the main menu, press to the ‘OK’ button for 3 seconds. Beside this, if no button pressed for 120 seconds, LCD screen brightness decreases to 10% by individually.
Type of protection | IP 20 | EN 60529 |
Safety class | ıı | EN 60664 |
Models | 12 Gang | LXA-112-16A |
20 Gang | LXA-120-16A | |
Product Detail | Mix Actuators With 12 Digital Inputs | |
Power Supply | Voltage | KNX Bus System |
Current Consumption | <10mA | |
Width Inspace Unit | 10 Module (1 Module = 18 mm) | |
Operating Mode | KNX Bus System | |
Output Connections | Conductor Cross Section | 0,25 - 6 mm² single core |
0,25 - 4 mm² stranded | ||
0,25 - 2,5 mm² stranded, with ferrule without plastic sleeve | ||
0,25 - 4 mm² stranded, with ferrule with plastic sleeve | ||
Max. torque | 0.5 Nm | |
KNX Bus connection terminal | 0,8 mm² Ø, solid core | |
Output | Number | 12 |
20 | ||
Switching voltage | AC 230V; @50/60 Hz | |
Switching capacity AC 250V | 16A, 105A Inrush | |
Maximum switching power | 4000 VA | |
Input Connections | Conductor Cross Section | 0,2 - 1,5 mm² solid |
0,2 - 1,5 mm² flexible | ||
0,25 - 1,5 mm² flexible, with ferrule without plastic sleeve | ||
0,25 - 0,75 mm² flexible, with ferrule with plastic sleeve | ||
Input | Number | 12 binary inputs |
State | Dry contact | |
Scanning voltage | DC 3V3 Pulsed | |
Current | 1 mA | |
Cable length | < 50m | |
Rated Values | Lamps Incandescent lamp load | 3680W |
Fluorescent lamp load | AC 250V 16A, 105A inrush current | |
Capacitive load | 70uF 10A cosQ=0.9 | |
Operating Elements | Character LCD | |
Buttons (3 pieces) | Right, Left, OK buttons, | |
Temperature range | Operation | -5°C / +45°C |
Storage | -20°C / +70°C | |
Humidity | Maximum air humidity | 85% no moisture consendation |
Flammability | Non-flammable product | |
Dimensions | L:67 x W:180 x H:90 mm | |
Weight | LXA-112-16A | 460 gr |
LXA-120-16A | 578 gr | |
Certification | KNX Certified |