The iluxusdesign KNX power supply generates a voltage of DC 30V and has an additional auxiliary voltage output. The integrated throttle decouples the KNX bus line from the 30 V DC auxiliary voltage. Both outputs are overload and short circuit proof. Any desired load distribution across the outputs is possible up to a maximum of 640 mA. The LED status shows the device status and overload. Resetting is done by pressing RESET button on the front of the device.
Type of protection | IP 20 | EN 60529 |
Safety class | ıı | EN 60664 |
Power Supply | Mains Voltage | AC 230V ±15 % @ 50 Hz |
Leakage Loss (Open Circuit) | 1,2 W | |
Leakage Loss (Normal) | 3,4 W | |
Power Consumption (Normal) | 23 W | |
Power Consumption (Max. Overload) | 42 W | |
Power Output | KNX Output Voltage | 28 ... 31 VDC (SELV) |
AUX Output Voltage | 28 ... 31 VDC (SELV) | |
Rated Current | 640 mA | |
Maximum Current (Total Output) | 1,2 A | |
Mains failure bridging time | > 100 ms | |
Efficiency at nominal load | 81 % | |
With in Space Unit | 4 Modules (1 Module = 18 mm) | |
Connections | Screw Terminals | 0,3 - 2,5 mm² |
Max. Torque | 0,4 Nm | |
KNX Connection Bus Terminal | 0,8 mm² Ø, solid core |
|
Installation | 35mm DIN Rail | |
Operating Element | Reset Button | Reset at the EIB/KNX Output |
Left LED (Green) | Output Voltage is OK | |
Middle LED (Red) | Overload or Short Circuit | |
Right LED (Red) | Reset | |
Temperature Range | Operation | (-5°C ... +45°C) |
Storage | (-20°C ... +70°C) | |
Humidity | Maximum air humidity | 5% ... 93% (non consendation) |
Flammability | Non-flammable product | |
Dimensions | L:70 W:90 H:65 mm | |
Weight | 206 gr | |
Standarts | EN50491-5-1 / -2 / -3, EN50581 | |
EN61000-6-2 / -3 | ||
EN61558-1 / -2-6 | ||
Certification | KNX Certified |